Konvision User Guide

LightSpace CMS integration with Konvision's range of monitors

Konvision Calibration

Calibration of Konvision displays with 3D LUT capability using LightSpace CMS is exceptionally simple.


Initial Setup

Calibration of Konvision displays with 3D LUT capability using LightSpace CMS is exceptionally simple.

Konvision Upload

The Upload menu is located under 'File/Upload'.


Profiling & Calibration

To activate the internal Patch Generator within the Konvision display navigate to the desired LightSpace CMS profiling mode - Calibration Interface, or Display Characterisation.

When the patch window is activate within LightSpace (the LightSpace CMS internal floating patch window has been made active by clicking the small colour display box when using Quick Profiling or Manual Measure modes) the internal patch generator within the Konvision display will mimic the colour displayed, using the patch size pre-set via the 'Upload' window.

Profiling can then be performed as normal, using the probe connected to LightSpace, with the Konvision monitor displaying the required patches.


LUT Upload

After profiling a Calibration LUT can be generated as normal, and with the LUT held within LightSpace navigate back to the 'Upload' menu, and with the 'NULL Cube' tick box un-ticked, the present LUT displayed within LightSpace can be 'Uploaded'. The location to upload to is selected via LUT slot drop-down menu, and includes standard colour space pre-sets, as well as User slots.

In this way, many different LUTs can be held within LightSpace CMS and quickly and easily uploaded into the Konvision display as needed, perfect for Look Management as well as accurate calibration to different standards.